Home Categories Send inquiry

G Series Environment-friendly Bio-Based TPU

Features

Bio-Based(25%-70% according to ASTM-D6866), Environment-friendly, Fast Setting Time, Excellent Elasticity

Application

Footwear, Electronics, Automotive, Sports&Recreation, Medical Care, Overmolding, Film&Sheet,  Compounding&Modifier, etc.
Properties

Standard

Unit

G185

G190

G195

G155D

G370

G375

G685

G690

G70

G75

G80

G85

G90

G95

Density

ASTM D792

g/cm3

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

1. 2

Hardness

ASTM D2240

Shore A/D

85/-

90/

94/-

-/55

72/-

77/-

86/-

91/-

70/-

75/-

80/-

85/-

90/-

95/-

Tensile Strength

ASTM D412

MPa

32

36

40

40

20

25

26

30

20

25

30

33

35

36

100%Modulus

ASTM D412

MPa

5

8

15

15

2

3

7

9

3

4

6

7

8

9

300%Modulus

ASTM D412

MPa

15

22

30

31

4

6

12

16

5

6

10

11

12

15

Elongation at Break

ASTM D412

550

450

390

350

700

650

550

500

650

600

550

500

500

500

Tear Strength

ASTM D624

kN/m

90

120

145

160

50

75

100

115

70

80

95

100

115

120

Tg

DSC

-30

-28

-25

-20

-43

-42

-25

-22

-35

-30

-25

-23

-20

-20

Bio-Based Content

ASTM D6866

41

37

33

28

30

28

21

20

75

67

65

60

54

50

NOTE: The above values are shown as typical values and should not be used as specifications.

Processing Guide

For optimum results, previous drying of the product during 3-4 hours at given temperature in the TDS. The products can be used for injection molding or extrusion, and please check more details in the TDS.
 Processing Guide for Injection Molding Processing Guide for Extrusion
Item Parameter Item Parameter
Nozzle(℃)

 Given in the TDS

Die(℃)  Given in the TDS
Metering Zone(℃) Adapter(℃)
Compression Zone(℃) Metering Zone (℃)
Feeding Zone(℃) Compression Zone (℃)
Injection Pressure(bar) Feeding Zone (℃)

Packaging

25KG/bag, 1250KG/pallet or 1500KG/pallet, processed wood pallet

Handling and Storage

Avoid processing material above recommended thermal processing temperatures. Good general ventilation should be sufficient for most conditions. Consider the use of local exhaust ventilation at processing emission points. 1. Avoid breathing thermal processing fumes and vapors 2. Mechanical handling equipment can cause formation of dust. Avoid breathing dust. 3. Use proper grounding techniques when handling this product to avoid electrostatic charges 4. Pellets on the floor may be slippery and cause falls Storage recommendations: To maintain product quality, store product in a cool, dry area. Keep in a tightly sealed container. HSE Information: Please take MSDS for reference.